{"id":13368,"date":"2025-07-18T15:20:17","date_gmt":"2025-07-18T08:20:17","guid":{"rendered":"https:\/\/vrenergy.vn\/?p=13368"},"modified":"2025-07-18T15:20:41","modified_gmt":"2025-07-18T08:20:41","slug":"solar-equipment-complete-catalog-for-complete-systems","status":"publish","type":"post","link":"https:\/\/vrenergy.vn\/en\/solar-equipment-complete-catalog-for-complete-systems\/","title":{"rendered":"Solar Equipment: Complete Catalog for Complete Systems"},"content":{"rendered":"<h1><b>Solar Energy Equipment: Complete Catalog &amp; System Selection Guide 2025<\/b><\/h1>\n<p><span style=\"font-weight: 400;\">Rising grid electricity costs and increasing demand for clean energy have motivated many households and businesses to explore solar energy systems. However, selecting appropriate equipment from hundreds of products in the market is not simple.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">This article provides comprehensive guidance on essential solar energy equipment, from main solar panels to supporting accessories, helping you build efficient systems and save long-term costs.<\/span><\/p>\n<h2><b>3 Popular Solar Energy System Types in Vietnam<\/b><\/h2>\n<h2><b>Grid-Tied Systems (On-Grid) &#8211; Electricity Cost Savings Solution<\/b><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13134\" src=\"https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-1-bai-14-vrenergy.jpg\" alt=\"\" width=\"2048\" height=\"1076\" title=\"\" srcset=\"https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-1-bai-14-vrenergy.jpg 2048w, https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-1-bai-14-vrenergy-600x315.jpg 600w, https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-1-bai-14-vrenergy-768x404.jpg 768w, https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-1-bai-14-vrenergy-1536x807.jpg 1536w\" sizes=\"auto, (max-width: 2048px) 100vw, 2048px\" \/><\/p>\n<p><span style=\"font-weight: 400;\">Grid-tied systems connect directly to the national electrical grid without requiring energy storage batteries. Electricity from solar panels is converted through inverters and used immediately or can be processed according to current policies when excess is generated.<\/span><\/p>\n<p><b>Advantages:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Lowest investment cost due to no battery storage requirement<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High efficiency with no energy losses through batteries<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Simple maintenance with fewer complex devices<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Can utilize excess electricity according to policies<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Disadvantages:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Does not operate during grid outages<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Dependent on energy policies<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">No backup power source<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Suitable for:<\/b><span style=\"font-weight: 400;\"> Households and businesses in areas with stable electrical grids, prioritizing cost savings.<\/span><\/p>\n<h2><b>Off-Grid Systems &#8211; Energy Independence<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Off-grid systems operate completely separate from the electrical grid, using battery storage to provide continuous electricity.<\/span><\/p>\n<p><b>Advantages:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Independent operation, not dependent on electrical grid<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Suitable for remote areas without grid electricity<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Complete energy autonomy<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Disadvantages:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High investment cost due to battery storage system comprising large proportion<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Requires careful calculation of battery storage capacity to meet demands<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">More complex maintenance, especially for battery storage<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Suitable for:<\/b><span style=\"font-weight: 400;\"> Remote areas, resorts, telecommunications stations, areas without electrical grid.<\/span><\/p>\n<h2><b>Hybrid Systems &#8211; Combining Both Advantages<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Hybrid systems combine grid-tied capabilities with energy storage, able to operate both with and without grid electricity.<\/span><\/p>\n<p><b>Advantages:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Saves electricity costs and provides backup power<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Flexible operation<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Optimizes energy usage<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Disadvantages:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Usually highest investment cost among residential system types<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Complex system requiring hybrid inverter<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Higher technical installation requirements<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Suitable for:<\/b><span style=\"font-weight: 400;\"> Premium households, businesses needing stable power supply, areas with frequent power outages.<\/span><\/p>\n<h2><b>Detailed Comparison Table of 3 System Types<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Criteria<\/b><\/td>\n<td><b>Grid-Tied<\/b><\/td>\n<td><b>Off-Grid<\/b><\/td>\n<td><b>Hybrid<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Investment cost<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Lowest<\/span><\/td>\n<td><span style=\"font-weight: 400;\">High<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Highest<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Complexity<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Simple<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Medium<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Complex<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Backup power<\/span><\/td>\n<td><span style=\"font-weight: 400;\">No<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Yes<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Yes<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Excess electricity handling<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Policy dependent<\/span><\/td>\n<td><span style=\"font-weight: 400;\">No<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Policy dependent<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Suitable for<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Cities<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Remote areas<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Flexible<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Main Equipment Catalog and Selection Criteria 2025<\/b><\/h2>\n<h2><b>Solar Panels &#8211; The &#8220;Heart&#8221; of the System<\/b><\/h2>\n<p><img decoding=\"async\" src=\"https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-2-bai-14-vrenergy.jpg\" alt=\"\" title=\"\"><\/p>\n<h2><b>Comparison of 3 Popular Panel Technologies<\/b><\/h2>\n<p><b>Mono PERC (Monocrystalline PERC)<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Efficiency: typically achieves 20-22%<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Advantages: High efficiency, good performance in low-light conditions<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Disadvantages: Higher cost<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Suitable for: Limited roof area, high efficiency requirements<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Polycrystalline (Poly)<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Efficiency: typically 15-19%<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Advantages: Affordable cost, stable technology<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Disadvantages: Lower efficiency, requires larger area<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Suitable for: Projects with wide roof areas, limited budgets<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Thin-Film<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Efficiency: typically below 15%<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Advantages: Thin and light, flexible, less efficiency impact from temperature increase compared to crystalline silicon panels<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Disadvantages: Low efficiency, requires very large area<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Suitable for: Special applications, roofs with weight limitations<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>Reputable Solar Panel Brands<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Highly rated solar panel brands in the market include:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>JinkoSolar<\/b><span style=\"font-weight: 400;\">: Brand with large global market share, stable quality products at competitive prices<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Longi Solar<\/b><span style=\"font-weight: 400;\">: Focuses on advanced technology, products typically have high efficiency<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Canadian Solar<\/b><span style=\"font-weight: 400;\">: Long-standing reputable brand with good customer support network<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>JA Solar<\/b><span style=\"font-weight: 400;\">: Specializes in high-quality panel production with good reliability<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Trina Solar<\/b><span style=\"font-weight: 400;\">: Provides diverse products suitable for various needs<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>Choosing Solar Panels Suitable for Vietnam&#8217;s Climate<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">In tropical climate conditions like Vietnam, consider:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Temperature coefficient<\/b><span style=\"font-weight: 400;\">: Choose panels with low temperature coefficient to minimize losses in hot weather<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Corrosion resistance<\/b><span style=\"font-weight: 400;\">: Prioritize panels with anodized aluminum frames and UV-resistant tempered glass<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Quality certifications<\/b><span style=\"font-weight: 400;\">: Prioritize panels meeting IEC 61215 and IEC 61730 standards. UL 1703 certification suitable for export projects or North American markets<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>Inverters &#8211; The &#8220;Brain&#8221; of Solar Systems<\/b><\/h2>\n<h2><b>Inverter Classification by Function<\/b><\/h2>\n<p><b>String Inverter<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Advantages: Low cost, easy installation and maintenance<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Disadvantages: Reduced efficiency with partial shading<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Suitable for: Roofs without shading, small to medium systems<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Micro Inverter<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Advantages: Optimizes individual panels, unaffected by shading<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Disadvantages: High cost, many devices requiring maintenance<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Suitable for: Complex roofs, with shading, high optimization requirements<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Hybrid Inverter<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Advantages: Integrates battery charging, smart energy management<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Disadvantages: High price, more complex<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Suitable for: Hybrid systems, energy storage requirements<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>Reputable Inverter Brands<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Huawei<\/b><span style=\"font-weight: 400;\">: Famous for smart technology and good monitoring capabilities<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>SMA<\/b><span style=\"font-weight: 400;\">: German brand with high quality and superior durability<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Growatt<\/b><span style=\"font-weight: 400;\">: Competitive price\/performance ratio, suitable for many projects<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Sungrow<\/b><span style=\"font-weight: 400;\">: Provides diverse products from residential to industrial<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>SolarEdge<\/b><span style=\"font-weight: 400;\">: Specializes in individual panel optimization solutions<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>Important Technical Criteria When Choosing Inverters<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Conversion efficiency<\/b><span style=\"font-weight: 400;\">: Prioritize high-efficiency inverters to minimize energy losses<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Number of MPPTs<\/b><span style=\"font-weight: 400;\">: More MPPTs help optimize when panels are installed in different directions<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>IP Rating<\/b><span style=\"font-weight: 400;\">: Need good protection standards against water and dust in Vietnam&#8217;s weather conditions<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Certifications<\/b><span style=\"font-weight: 400;\">: Need international certifications and compliance with domestic standards<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>Battery Storage Systems &#8211; Continuous Energy<\/b><\/h2>\n<h2><b>Battery Storage Classification by Technology<\/b><\/h2>\n<p><b>Lead-acid (AGM, GEL)<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Advantages: Low cost, mature technology<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Disadvantages: Shorter lifespan, lower efficiency<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Applications: Budget-limited systems, small capacity<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Lithium (LiFePO4)<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Advantages: High lifespan, good efficiency<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Disadvantages: High investment cost<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Applications: Premium systems, high reliability requirements<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>Battery Storage Lifecycle Cost Comparison<\/b><\/h2>\n<table>\n<tbody>\n<tr>\n<td><b>Battery Type<\/b><\/td>\n<td><b>Price Characteristics<\/b><\/td>\n<td><b>Charge Cycles<\/b><\/td>\n<td><b>Lifespan<\/b><\/td>\n<td><b>Notes<\/b><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Lead-acid<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Low<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Limited<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Shorter<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Requires frequent replacement<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">LiFePO4<\/span><\/td>\n<td><span style=\"font-weight: 400;\">High<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Many<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Long<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Long-term costs may be lower<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Important Supporting Accessories &amp; Components<\/b><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13142\" src=\"https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-3-bai-14-vrenergy.jpg\" alt=\"\" width=\"2048\" height=\"1076\" title=\"\" srcset=\"https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-3-bai-14-vrenergy.jpg 2048w, https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-3-bai-14-vrenergy-600x315.jpg 600w, https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-3-bai-14-vrenergy-768x404.jpg 768w, https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-3-bai-14-vrenergy-1536x807.jpg 1536w\" sizes=\"auto, (max-width: 2048px) 100vw, 2048px\" \/><\/p>\n<h2><b>Mounting Frames &amp; Installation Systems<\/b><\/h2>\n<p><b>Frame materials:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Aluminum alloy: Light, good corrosion resistance<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Galvanized steel: Durable, cheaper but heavier<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Installation methods:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Sloped roofs: Use aluminum rails fixed parallel to roof<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Flat roofs: Need support frames with appropriate tilt angles<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Ground installation: Requires concrete foundation, sturdy steel frames<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>Protection &amp; Safety Equipment<\/b><\/h2>\n<p><b>Lightning protection systems (SPD)<\/b><span style=\"font-weight: 400;\">: Need SPD on both DC and AC sides to protect equipment from indirect lightning strikes.<\/span><\/p>\n<p><b>Circuit breakers:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">MCB: AC circuit overload protection<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">DC Breaker: DC circuit disconnection during maintenance<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">RCBO: Leakage protection, important for rooftop systems<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Grounding system<\/b><span style=\"font-weight: 400;\">: Need separate grounding for solar systems according to technical standards.<\/span><\/p>\n<h2><b>Monitoring &amp; Control Systems<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Monitoring software<\/b><span style=\"font-weight: 400;\">: Most modern inverters have mobile applications to track electricity production, early fault detection<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Data logger<\/b><span style=\"font-weight: 400;\">: Device collecting operational data, sending alerts during failures<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>IoT solutions<\/b><span style=\"font-weight: 400;\">: Smart systems can automatically adjust consumption loads based on solar panel production<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>Standard Installation Process &amp; Important Notes<\/b><\/h2>\n<h2><b>Step 1: Site Survey &amp; System Design<\/b><\/h2>\n<p><b>Installation location assessment:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Roof direction: Optimal is South-facing, Southeast and Southwest acceptable<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Tilt angle: Suitable for geographical location of each region<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Shading: Avoid shading from trees, tall buildings during sunny hours<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Capacity calculation<\/b><span style=\"font-weight: 400;\">: Based on long-term electricity bills to determine average consumption needs, then calculate appropriate system capacity.<\/span><\/p>\n<h2><b>Step 2: Safe &amp; Technically Correct Construction<\/b><\/h2>\n<p><b>Installation procedure:<\/b><\/p>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Install mounting frames and secure firmly<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Install panels on frames, ensuring safety distances<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Connect DC wiring according to correct polarity<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Install inverter in well-ventilated location, avoiding direct sunlight<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Connect AC to electrical panel according to residential electrical standards<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ol>\n<p><b>Safety standards:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Use specialized cables for solar systems<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Install independent grounding system<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Use complete protective equipment<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>Step 3: System Acceptance &amp; Handover<\/b><\/h2>\n<p><b>Technical inspection:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Test DC and AC voltages<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Check insulation<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Test inverter and monitoring system operation<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Legal procedures<\/b><span style=\"font-weight: 400;\">: For grid-tied systems, need to complete procedures according to current regulations.<\/span><\/p>\n<h2><b>Important Notes for Installation in Vietnam<\/b><\/h2>\n<p><b>Tropical climate:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Ensure good ventilation for inverters<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Use corrosion-resistant materials in humid environments<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Consider storm impact when designing mounting frames<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Technical standards<\/b><span style=\"font-weight: 400;\">: Comply with electrical safety standards and solar system regulations.<\/span><\/p>\n<h2><b>Solar Energy System Investment Cost &amp; Efficiency 2025<\/b><\/h2>\n<h2><b>Cost Overview by Installation Capacity<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Solar energy system costs depend on many factors:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Small systems (3-5kW)<\/b><span style=\"font-weight: 400;\">: Suitable for households with average electricity consumption<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Medium systems (5-10kW)<\/b><span style=\"font-weight: 400;\">: Appropriate for households with high electricity consumption or small businesses<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Large systems (over 10kW)<\/b><span style=\"font-weight: 400;\">: For businesses, factories with large electricity consumption needs<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>Profitability Analysis<\/b><\/h2>\n<p><b>Factors affecting efficiency:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Current electricity consumption level<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Light conditions in the area<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Equipment quality and degradation over time<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Government support policies<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Payback period<\/b><span style=\"font-weight: 400;\">: Usually varies depending on system type and specific project conditions.<\/span><\/p>\n<h2><b>Comparison with Traditional Grid Electricity<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Long-term, solar energy systems have cost advantages with low operating costs after completing initial investment, while grid electricity costs tend to increase over time.<\/span><\/p>\n<h2><b>System Maintenance &amp; Performance Optimization<\/b><\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13146\" src=\"https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-4-bai-14-vrenergy.jpg\" alt=\"\" width=\"2048\" height=\"1076\" title=\"\" srcset=\"https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-4-bai-14-vrenergy.jpg 2048w, https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-4-bai-14-vrenergy-600x315.jpg 600w, https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-4-bai-14-vrenergy-768x404.jpg 768w, https:\/\/vrenergy.vn\/wp-content\/uploads\/2025\/06\/hinh-4-bai-14-vrenergy-1536x807.jpg 1536w\" sizes=\"auto, (max-width: 2048px) 100vw, 2048px\" \/><\/p>\n<h2><b>Regular Maintenance Schedule<\/b><\/h2>\n<p><b>Monthly:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Check electricity production through monitoring applications<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Observe solar panel surface condition<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Quarterly:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Clean panels with clean water<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Check cable connections<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Check inverter operation<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Annually:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Comprehensive system inspection by technicians<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Measure performance and compare with design<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Maintain protection equipment<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>Common Troubleshooting<\/b><\/h2>\n<p><b>Reduced panel performance:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Causes: Dirt, shading, panel damage<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Solutions: Clean, remove shading, replace damaged panels<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<p><b>Inverter errors:<\/b><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Causes: Overheating, connection errors, component failure<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Solutions: Improve ventilation, check connections, contact warranty service<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>System Upgrade &amp; Expansion Capability<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>System expansion<\/b><span style=\"font-weight: 400;\">: Can add panels if inverter has excess capacity and sufficient installation area<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Technology upgrades<\/b><span style=\"font-weight: 400;\">: Add battery storage or upgrade smart inverters for existing systems<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>Solar Technology Trends 2025-2030<\/b><\/h2>\n<h2><b>Next-Generation Solar Panel Technology<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Perovskite panels<\/b><span style=\"font-weight: 400;\">: New technology being researched with high efficiency potential, but still needs time to stabilize durability<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Tandem panels<\/b><span style=\"font-weight: 400;\">: Combine multiple panel technologies to increase overall efficiency<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Transparent panels<\/b><span style=\"font-weight: 400;\">: Applications on windows and building glass, generating energy without obstructing views<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>Advanced Storage Solutions<\/b><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>New battery technology<\/b><span style=\"font-weight: 400;\">: New storage battery types with high capacity and long lifespan being developed<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>AI applications<\/b><span style=\"font-weight: 400;\">: Smart energy management systems using artificial intelligence to optimize operations<\/span><span style=\"font-weight: 400;\">\n<p><\/span><\/li>\n<\/ul>\n<h2><b>Market &amp; Policy Forecasts<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">With manufacturing technology development, equipment costs tend to decrease over time. Renewable energy support policies are also being developed with attention.<\/span><\/p>\n<h2><b>FAQ &#8211; Frequently Asked Questions About Solar Energy Equipment<\/b><\/h2>\n<h2><b>Equipment &amp; Technology Questions<\/b><\/h2>\n<p><b>Which panels are best for Vietnam&#8217;s climate?<\/b><b><br \/>\n<\/b><span style=\"font-weight: 400;\"> Mono PERC panels from reputable brands are suitable choices with high efficiency and good durability in tropical conditions.<\/span><\/p>\n<p><b>What inverter type should I choose for residential systems?<\/b><b><br \/>\n<\/b><span style=\"font-weight: 400;\"> String inverters from reputable brands typically meet household needs well with reasonable price\/performance ratios.<\/span><\/p>\n<p><b>Are LiFePO4 storage batteries worth investing in?<\/b><b><br \/>\n<\/b><span style=\"font-weight: 400;\"> LiFePO4 batteries have high lifespan and good efficiency, suitable for systems requiring high reliability.<\/span><\/p>\n<h2><b>Cost &amp; Efficiency Questions<\/b><\/h2>\n<p><b>What are solar energy system installation costs?<\/b><b><br \/>\n<\/b><span style=\"font-weight: 400;\"> Costs depend on capacity, equipment quality, and installation methods. Need specific quotes from suppliers.<\/span><\/p>\n<p><b>What is the actual payback period?<\/b><b><br \/>\n<\/b><span style=\"font-weight: 400;\"> Payback period depends on many factors like electricity consumption level, light conditions, and support policies.<\/span><\/p>\n<p><b>Can excess electricity be utilized?<\/b><b><br \/>\n<\/b><span style=\"font-weight: 400;\"> Depending on current policies, users may benefit from excess electricity according to regulated mechanisms.<\/span><\/p>\n<h2><b>Installation &amp; Maintenance Questions<\/b><\/h2>\n<p><b>Can solar be installed on metal roofs?<\/b><b><br \/>\n<\/b><span style=\"font-weight: 400;\"> Yes, if roof structure is sufficiently strong. Technical assessment needed before installation.<\/span><\/p>\n<p><b>Do systems operate noisily?<\/b><b><br \/>\n<\/b><span style=\"font-weight: 400;\"> Inverters have slight noise when operating but typically don&#8217;t affect daily activities.<\/span><\/p>\n<p><b>What is the average system lifespan?<\/b><b><br \/>\n<\/b><span style=\"font-weight: 400;\"> Solar panels have long lifespans, inverters typically operate stably for many years. With proper maintenance, systems can operate efficiently for extended periods.<\/span><\/p>\n<h2><b>Towards Sustainable Energy Solutions<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Choosing appropriate solar energy equipment requires careful consideration of usage needs, installation conditions, and investment budget. With continuous technology development, solar energy solutions are becoming increasingly efficient and economical.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">To make accurate investment decisions, consulting experts and reputable suppliers will help you get optimal systems that meet long-term energy needs sustainably and economically.<\/span><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Solar Energy Equipment: Complete Catalog &amp; System Selection Guide 2025 Rising grid electricity costs and increasing demand for clean energy have motivated many households and businesses to explore solar energy systems. However, selecting appropriate equipment from hundreds of products in the market is not simple. This article provides comprehensive guidance on essential solar energy equipment,&#8230;<\/p>\n","protected":false},"author":1,"featured_media":13369,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[37],"tags":[],"class_list":["post-13368","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"_links":{"self":[{"href":"https:\/\/vrenergy.vn\/en\/wp-json\/wp\/v2\/posts\/13368","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vrenergy.vn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/vrenergy.vn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/vrenergy.vn\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vrenergy.vn\/en\/wp-json\/wp\/v2\/comments?post=13368"}],"version-history":[{"count":2,"href":"https:\/\/vrenergy.vn\/en\/wp-json\/wp\/v2\/posts\/13368\/revisions"}],"predecessor-version":[{"id":13374,"href":"https:\/\/vrenergy.vn\/en\/wp-json\/wp\/v2\/posts\/13368\/revisions\/13374"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vrenergy.vn\/en\/wp-json\/wp\/v2\/media\/13369"}],"wp:attachment":[{"href":"https:\/\/vrenergy.vn\/en\/wp-json\/wp\/v2\/media?parent=13368"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/vrenergy.vn\/en\/wp-json\/wp\/v2\/categories?post=13368"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/vrenergy.vn\/en\/wp-json\/wp\/v2\/tags?post=13368"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}